TMR-E12 with error memory, 230 V AC, 1 changeover contact

Description

The thermistor relay is used as protection relay for motors against thermal overload (inadmissible heating). This heating might be caused by mechanical overload on the shaft or when operating the motor with inadmissible voltages. A PTC thermistor is used as sensor. It should be mounted to the part of the motor that heats most in case of overload (e.g. integrated in motor winding). The device can also be used for motors with integrated thermo switch. Integrated fault memory with reset key at the front.

  • Variant:
  • 230 V AC
  • 1 changeover contact (DPST)
Technical Data
General Data
230 V AC
10 ms
12 V
1 mA
1.8 kOhm
3.0 kOhm, +/- 5%
1 (SPDT) changeover contact
250 V
4 A
1 x 107
1 x 105
1200 cycles/h
Green and red LED
22.5 x 75 x 95 mm
150 g
0 °C to 55 °C
-20 °C to 70 °C
IP40 / IP20
Check US distributor inventory
Part number
11031605
4250184118671
Downloads
  • 3D-Data - Registration required -
  • Data sheet
  • ePLAN data - Registration required -
× Do you have any questions?